DMD1050 Satellite Modem Board Web Browser
TRACKING RATE {0.5 to 6.0}
Allows the user to set the rate at which the commands to increase
or decrease Transmit Power are sent. Each command will result
in a 0.5 dB increase or decrease in Transmit Power from the
remote transmitter. The tracking rate is adjustable from 0.5 dB
per minute to 6.0 dB per minute in 0.5 dB steps. (Only
available when EFAUPC is selected as the framing)
LOCAL CL ACTION {HOLD, NOMINAL, MAXIMUM}
This allows the user to set the Remote Transmit Power Setting to
be used when the local modem receiver loses lock. The setting
can be 'HOLD' (no action taken), 'NOMINAL' (the nominal
Transmit Power Setting is used), and 'MAXIMUM' (the
maximum Transmit Power Setting is used). (Only available
when EFAUPC is selected as the framing)
REMOTE CL ACTION {HOLD, NOMINAL, MAXIMUM}
This allows the user to set the Local Transmit Power Setting to
be used when the remote modem receiver loses lock. The setting
can be 'HOLD' (no action taken), 'NOMINAL' (the nominal
Transmit Power Setting is used), and 'MAXIMUM' (the
maximum Transmit Power Setting is used).
REMOTE AUPC (menu) The 'REMOTE AUPC CONFIGURATION' Menu contains the
remote configuration parameters for the AUPC Function.
Remote AUPC menus are only available when modem is
configured for EF AUPC
AUPC MODE {DISABLE, EFDATA}
Allows the user to enable or disable the AUPC Function of the
remote modem. The remote AUPC Function is the response of
the local modem to commands for an increase or decrease of the
Transmit Power in 0.5 dB steps and the command to change to
the setting indicated in the 'REMOTE CL ACTION' Menu of the
remote modem upon receiver loss of lock.
LOOPBACK {DISABLE, ENABLE}
Allows the user to enable or disable the Baseband Loopback Test
Mode of the remote modem.
TX 2047 TEST {DISABLE, ENABLE}
Allows the user to enable or disable the Transmit 2047 Pattern
Test Mode of the remote modem.
RX 2047 BER: Reports the BER measurement of the receiver 2047 Pattern Test
Mode of the remote modem. BER is reported from the 1x10
-5
to
1x10
-7
in tenth decade steps. If the pattern does not synchronize
or is out of range, ‘NO DATA’ will be displayed.
When modems are configured for Radyne AUPC, the remote Eb/No will be
displayed in the Monitor Menus.
IMPORTANT