User Manual
Chapter 2. Installation
Page 2-42 P/N 2349-72712-01
2.6.2. Single System Management
This paragraph explains the configuration procedures of the NMS-4000 as a single system
management.
The configuration process has the following steps:
a. Install the NMS-4000. Choose all three components in the components selection screen.
Paragraph 2.6.1 provides detailed instructions.
b. Run the Designer and configure the devices and system information.
When saving the system, the file should be named after the system name and in the
default directory. Paragraph 2.3 explains the Designer configuration process
c. Run the GeoBuilder and configure system and site related information. Paragraph 2.4
explains the GeoBuilder configuration process.
The Supervisor Configuration dialog and Site Manager Configuration dialog should be
configured to the IP address of the computer, which the NMS-4000 is installed at.
d. Copy the system internal configuration files (Refer to paragraph 2.2.4) to the system
directory Scopus\NMS\Config\[system name].
NOTE
The [system name] in the above directory is composed of:
name of system, one space, a hyphen, one space and the rack serial number.
The Directory should not be renamed. A change in the directory name may lead to
system failure!
e. Configure the System Manager as described in paragraph 2.5.
f. Check the file NMS-4000.ini found in
Scopus\NMS\Config\[system name]\NMS-4000.ini for the following parameter:
section [SNMP AGENT]
parameter enable information exporter feature
value should be 1.
2.6.3. Remote Management
This paragraph explains the configuration procedures of the NMS-4000 as a remote system
management.
Remote system management is a system with at least two computers. The first computer is
the client computer and has the NMS-4000 installed in a single system management mode.
Refer to paragraph 2.6.2 for more details. A remote computer in a different location manages
the system though the client computer. The remote computer should be connected to the
same network as the client computer.
The configuration of a remote management system has the following steps:
a. A single system management must be installed on one or more client computers.
Refer to paragraph 2.6.2 for more details.
b. Install the NMS-4000 on a remote computer. The NMS, Navigator, Designer, Geo-
Builder components should be selected on the ‘Select Components’ installation screen.
The remote computer has to be connected to the same network of the client computer.
Refer to paragraph 2.6.1 for detailed instructions.