DM240XR High-Speed Digital Modulator Remote Operations
MN-DM240XRRevision 13 9–9
Opcode: <2405h> Query a Modulator’s Latched Alarms
Query response
<1>
Latched Major
Alarm
Bit 0 = Spare
Bit 1 = Transmit Oversample PLL Lock
Bit 2 = FPGA Config Error
Bit 3 = IF Synthesizer PLL Lock
Bit 4 = External Reference PLL Lock
Bit 5 = Composite PLL Lock
Bit 6 = Symbol PLL Lock
Bit 7 = Spare
0 = Pass, 1 = Fail
<1>
Latched Minor
Alarm
Bit 0 = Terrestrial Ethernet data activity detect
Bit 1 = Loss Terrestrial Clock
Bit 2 = Loss Terrestrial Data
Bit 3 = FIFO Error
Bit 4 = Output Level
Bit 5 = Terrestrial Framing Error
Bit 6 = Terr Ethernet jitter buffer underflow
Bit 7 = Terr Ethernet jitter buffer overflow
0 = Pass, 1 = Fail
<1>
Latched Common
Fault
Bit 0 = -12 V Alarm
Bit 1 = +12 V Alarm
Bit 2 = +5 V Alarm
Bit 3 = Spare
Bit 4 = Spare
Bit 5 = Spare
Bit 6 = Spare
Bit 7 = Spare
0 = Pass, 1 = Fail
Opcode: <2408h> Query a Modulator’s Current Alarms
Query response
<1>
Major Alarm
Bit 0 = Spare
Bit 1 = Transmit Oversample PLL Lock
Bit 2 = FPGA Config Error
Bit 3 = IF Synthesizer PLL Lock
Bit 4 = External Reference PLL Lock
Bit 5 = Composite PLL Lock
Bit 6 = Symbol PLL Lock
Bit 7 = Spare
0 = Pass, 1 = Fail
<1>
Minor Alarm
Bit 0 = Terrestrial Ethernet data activity detect
Bit 1 = Loss Terrestrial Clock
Bit 2 = Loss Terrestrial Data
Bit 3 = FIFO Error
Bit 4 = Output Level
Bit 5 = Terrestrial Framing Error
Bit 6 = Terr Ethernet jitter buffer underflow
Bit 7 = Terr Ethernet jitter buffer overflow